What is the CLEARLINE Auto and Cleaning Mode
The CLEARLINE System automatically and continuously calculates the optimal level of chlorine for marine growth prevention based on multiple input parameters including vessel seawater flow rates, raw water pump operation, gas/air presence, key electrical parameter levels, and environmental temperature.
During normal operation the CLEARLINE System will flash the word "Cleaning" and the green Cleaning LED will be lit. This indicates the CLEARLINE System is generating chlorine and protecting the vessel’s raw water circuits from marine growth. The System will display the flow rate at the output of the CLEARLINE System in gallons per minute (GPM) or liters per minute (LPM). If the flow rate drops below 4 GPM, then the display will indicate Min Flow. The CLEARLINE System will automatically cease chlorine output during periods of Min Flow (1–3 GPM), or No Flow (0 GPM).